H13-611 exam Format | Course Contents | Course Outline | exam Syllabus | exam Objectives
Exam Code: H13-611, H13-611_V5.0-ENU
Exam Name: HCIA-Storage V5.0
Exam Level: Associate (Entry-level)
Duration: 90 minutes
Number of Questions: Approximately 60
Passing Score: 600/1000
Exam Format: Multiple-choice (single and multiple answers), drag-and-drop, and scenario-based questions
Language: Available in English and Chinese
Domain 1: Understanding Storage Technology Trends
- Latest storage technologies and trends.
- Storage technologies for AI, big data, and cloud.
- Introduction to storage ecosystems.
Domain 2: Understanding Basic Storage Technologies
- Storage architecture, devices, and protocols.
- Fundamental principles of storage design and implementation.
- Storage networking technologies (e.g., FCSAN, IPSAN).
Domain 3: Understanding Huawei Intelligent Storage Products and Features
- Features and functionalities of Huawei storage products.
- Configuration and management of Huawei storage solutions.
Domain 4: Understanding Storage System O&M Management
- Operation and maintenance of storage systems in data centers.
- Business continuity solutions and their applications.
- Storage system troubleshooting and management.
1. Understanding Storage Technology Trends (5%)
- Evolution of storage technologies in the context of AI, big data, and cloud computing.
- Introduction to storage ecosystems and their components.
- Industry trends impacting storage (e.g., intelligent storage, software-defined storage).
- Storage requirements for AI-driven workloads.
- Big data storage architectures and scalability.
- Cloud storage models (public, private, hybrid).
- Storage ecosystem components (hardware, software, protocols).
- Software-Defined Storage (SDS): A storage architecture that separates storage management from underlying hardware.
- Cloud Storage: Scalable storage services hosted on cloud infrastructure.
- Big Data: Large, complex datasets requiring specialized storage solutions.
- Artificial Intelligence (AI): Use of machine learning and analytics in storage optimization.
- Storage Ecosystem: Interconnected components (e.g., servers, storage devices, networks) for data management.
2. Understanding Basic Storage Technologies (50%)
- Storage system architectures and components.
- Storage devices, media, and their characteristics.
- Storage networking technologies (FCSAN, IPSAN, NAS).
- Data organization and access methods.
- Basic storage principles (e.g., RAID, data protection).
- Storage System Architecture:
- Controller-based vs. distributed architectures.
- Block, file, and object storage.
- Storage Devices:
- Hard Disk Drives (HDDs), Solid-State Drives (SSDs), and tape storage.
- Storage interfaces (SATA, SAS, NVMe).
- Storage Networking:
- Fibre Channel SAN (FCSAN): Components, zoning, and topologies.
- IP SAN (iSCSI): Configuration and use cases.
- Network-Attached Storage (NAS): Protocols (NFS, CIFS/SMB).
- Data Organization:
- Logical Unit Number (LUN) management.
- File systems and their roles.
- RAID Technologies:
- RAID levels (0, 1, 5, 6, 10, 50).
- RAID performance and redundancy.
- Data Protection:
- Backup and recovery methods.
- Snapshot and replication technologies.
- Block Storage: Data stored in fixed-size blocks, used in SAN environments.
- File Storage: Data stored in hierarchical file structures, used in NAS.
- Object Storage: Data stored as objects with metadata, used in cloud environments.
- Fibre Channel (FC): High-speed network protocol for SANs.
- iSCSI (Internet Small Computer Systems Interface): IP-based protocol for SAN storage.
- NAS (Network-Attached Storage): File-level storage accessible over a network.
- RAID (Redundant Array of Independent Disks): Technology for data redundancy and performance.
- LUN (Logical Unit Number): Identifier for a storage device or partition.
- Snapshot: Point-in-time copy of data for backup or recovery.
- NVMe (Non-Volatile Memory Express): High-performance storage protocol for SSDs.
- Zoning: Logical grouping of devices in a SAN for access control.
- CIFS/SMB: Protocols for file sharing in Windows environments.
- NFS (Network File System): Protocol for file sharing in UNIX/Linux environments.
3. Understanding Huawei Intelligent Storage Products and Features (35%)
- Overview of Huawei storage products (e.g., OceanStor series).
- Key features of Huawei intelligent storage solutions.
- Configuration and management of Huawei storage systems.
- Application scenarios for Huawei storage products.
- Huawei Storage Products:
- OceanStor Dorado (all-flash storage).
- OceanStor Pacific (mass data storage).
- OceanStor (hybrid flash storage).
- Intelligent Features:
- SmartTier: Automated data tiering for performance optimization.
- SmartDedupe: Data deduplication for storage efficiency.
- SmartCompression: Real-time data compression.
- HyperMetro: Active-active storage for high availability.
- HyperSnap: Snapshot technology for data protection.
- Configuration and Management:
- Storage system initialization and setup.
- Storage pool and LUN configuration.
- DeviceManager and eService for management.
- Use Cases:
- Enterprise data centers.
- Virtualization and cloud environments.
- Database and big data analytics.
- OceanStor: Huawei’s flagship storage product line.
- Dorado: Huawei’s all-flash storage for high-performance workloads.
- SmartTier: Dynamic data placement across storage tiers.
- HyperMetro: Dual-active storage solution for zero data loss.
- SmartDedupe: Elimination of redundant data to save space.
- SmartCompression: Inline data compression for efficiency.
- HyperSnap: Huawei’s snapshot technology for backups.
- DeviceManager: Huawei’s storage management software.
- eService: Cloud-based management and maintenance platform.
- Storage Pool: Logical grouping of physical storage resources.
4. Understanding Storage System O&M Management (10%)
- Storage system operation and maintenance (O&M) processes.
- Business continuity and disaster recovery solutions.
- Troubleshooting common storage issues.
- Performance monitoring and optimization.
- O&M Processes:
- System monitoring and health checks.
- Capacity planning and resource allocation.
- Business Continuity:
- Backup and restore procedures.
- Disaster recovery (DR) planning and replication.
- Troubleshooting:
- Diagnosing connectivity issues in SAN/NAS environments.
- Resolving performance bottlenecks.
- Performance Optimization:
- Monitoring IOPS, latency, and throughput.
- Tuning storage configurations for workloads.
- O&M (Operation and Maintenance): Routine tasks to ensure system reliability.
- Disaster Recovery (DR): Strategies to restore data and services after failures.
- Replication: Copying data to a secondary site for redundancy.
- IOPS (Input/Output Operations Per Second): Measure of storage performance.
- Latency: Time taken for a storage operation to complete.
- Throughput: Data transfer rate in a storage system.
- Backup: Copy of data for recovery purposes.
- High Availability (HA): System design to minimize downtime.
100% Money Back Pass Guarantee

H13-611 PDF demo Questions
H13-611 demo Questions
Killexams.com exam Questions and Answers
Question: 562
A video streaming service uses Huawei OceanStor 9000 to store 50 PB of content. The administrator enables SmartDedupe to optimize capacity for metadata-heavy workloads, which have a 40% deduplication ratio. The workload includes 80% sequential reads and 20% random writes with 16 KB blocks. Which deduplication settings will balance performance and capacity savings?
1. Inline deduplication with 16 KB chunk size
2. Inline deduplication with variable-length chunking
3. Post-process deduplication with 16 KB chunk size
4. Post-process deduplication with variable-length chunking
Answer: C
Explanation: For sequential read-heavy workloads, post-process deduplication avoids write performance degradation, as it processes data after storage. A 16 KB chunk size aligns with the block size, maximizing deduplication efficiency for metadata. Inline deduplication impacts write performance, and variable-length chunking increases processing overhead, making it less suitable for this workload.
Question: 563
An enterprise deploys Huawei Dorado V6 for a high-performance SAP HANA database requiring 800,000 IOPS and 0.2 ms latency. The administrator configures a RAID 5 group with 10 SSDs, each providing 60,000 IOPS and 0.1 ms latency. Assuming a 60% read and 40% write workload, does the configuration meet the performance requirements?
1. The configuration meets both IOPS and latency requirements
2. The configuration meets IOPS but not latency requirements
3. The configuration meets latency but not IOPS requirements
4. The configuration meets neither IOPS nor latency requirements
Answer: C
Explanation: RAID 5 with 10 SSDs provides 10 * 60,000 = 600,000 IOPS for reads. For writes, RAID 5 has a penalty of 4 I/Os per write (2 reads + 2 writes), so write IOPS = 600,000 / 4 = 150,000. For 800,000 IOPS (60% read = 480,000; 40% write = 320,000), the configuration supports 600,000 read IOPS but only 150,000 write IOPS, falling short. Latency remains below 0.2 ms, as SSD latency (0.1 ms) plus RAID 5 overhead is minimal. Thus, latency is met, but IOPS is not.
Question: 564
A machine learning startup is deploying a deep learning model for image recognition, requiring a storage system to handle 20 TB of training data with 80% sequential read operations. The system must support TensorFlow integration and provide 500,000 IOPS at 0.2 ms latency. Huaweis OceanStor Dorado V6 is configured with a 4:1 read/write ratio and RAID 6. Which storage configuration best meets the AI-driven workloads requirements?
1. Enable SmartCache with 256 GB SSD cache per controller
2. Configure HyperSnap for frequent data snapshots
3. Implement SmartDedupe with a 3:1 reduction ratio
4. Use HyperCDP for continuous data protection
Answer: A
Explanation: SmartCache with 256 GB SSD cache per controller enhances sequential read performance by caching frequently accessed data, meeting the 500,000 IOPS and 0.2 ms latency requirements for the TensorFlow-integrated deep learning workload. HyperSnap and HyperCDP focus on data protection, not performance, while SmartDedupe may introduce latency, unsuitable for high-IOPS AI workloads.
Question: 565
A Huawei OceanStor V5 storage system hosts a LUN for a transactional database with a snapshot schedule of every 2 hours and a retention period of 24 hours. The LUN is 5 TB, thin-provisioned, with 3 TB of data, and uses copy-on-write snapshots. The storage pool has 12 TB of free space. The administrator notices that snapshot creation fails during high write activity. Which of the following actions can resolve this issue?
1. Increase the metadata cache size for snapshot operations
2. Reduce the snapshot frequency to every 4 hours
3. Enable SmartDedupe to reduce snapshot storage usage
4. Schedule snapshots during low write activity periods
Answer: A, B, D
Explanation: Increasing metadata cache size improves snapshot performance by reducing contention for metadata updates during high write activity. Reducing snapshot frequency to every 4 hours decreases metadata and space demands, preventing failures. Scheduling snapshots during low write activity minimizes contention with application I/O, ensuring successful creation. SmartDedupe reduces data size but does not address metadata or contention issues for snapshots, as deduplication is separate from snapshot mechanics.
Question: 566
A manufacturing company is deploying a Huawei Dorado storage system to support an ERP application. The application requires block storage with a latency of less than 0.3 ms and a throughput of 5 GB/s. The IT team is configuring storage interfaces and RAID levels. Which of the following configurations would best meet these requirements while ensuring high availability?
1. SAS interface with RAID 5
2. NVMe interface with RAID 10
3. SATA interface with RAID 6
4. FC interface with RAID 1
Answer: B
Explanation: The ERP applications requirements of sub-0.3 ms latency and 5 GB/s throughput demand a high-performance storage interface and RAID configuration. The NVMe interface, with its low latency and high bandwidth (up to 3.5 GB/s per drive), paired with RAID 10, provides both high performance (via striping) and high availability (via mirroring). SAS with RAID 5 and SATA with RAID 6 are slower and incur write penalties, making them unsuitable for low-latency needs. FC with RAID 1, while reliable, is limited by lower bandwidth compared to NVMe, making it less optimal for this throughput requirement.
Question: 567
A company uses a Huawei OceanStor V5 storage system to provide file sharing for 150 Linux servers via NFS. The NFS share is configured on a 4 TB LUN with thin provisioning, and the workload involves frequent small-file writes (4K to 8K). The administrator notices that file write performance degrades during peak hours. Which of the following configurations or actions can Improve NFS write performance for this workload?
1. Enable NFS async mode to reduce client wait times
2. Increase the LUNs stripe size to 256 KB for better throughput
3. Configure NFSv4 with delegation to reduce server load
4. Enable SmartCache with SSDs to accelerate small-file writes
Answer: A, C, D
Explanation: NFS async mode reduces client wait times by acknowledging writes before they are committed, improving performance for small-file writes. NFSv4 delegation allows clients to cache file operations locally, reducing server load and improving performance. SmartCache with SSDs accelerates small-file writes by leveraging high-speed SSDs for caching. A 256 KB stripe size is unsuitable for small-file writes, as it increases overhead for partial stripe writes, degrading performance.
Question: 568
A storage administrator troubleshooting a Huawei OceanStor 5500 V5 system notices that a SAN- attached host cannot access a LUN. The hosts HBA logs show repeated login failures, and the storage systems DeviceManager indicates that the LUN is mapped to the host group. Which of the following steps should the administrator take to resolve this connectivity issue?
1. Verify the zoning configuration on the Fibre Channel switch
2. Check the hosts multipathing software configuration for correct failover settings
3. Reboot the storage controller to reset the host mapping
4. Ensure the LUNs WWN is correctly registered in the hosts initiator settings
Answer: A, B, D
Explanation: LUN access failures suggest a connectivity or configuration issue. Verifying the zoning configuration on the Fibre Channel switch ensures the host and storage can communicate. Checking the hosts multipathing software ensures proper failover and path management. Ensuring the LUNs WWN is registered in the hosts initiator settings confirms correct identification. Rebooting the controller is disruptive and unlikely to resolve a mapping issue if the LUN is already mapped.
Question: 569
A gaming company is building a storage ecosystem for real-time analytics, handling 500 TB of player data. The ecosystem uses Huaweis OceanStor Pacific for object storage and FusionStorage for block storage. The system requires 4 million IOPS and data isolation. Which features ensure performance and isolation?
1. FusionStorages QoS policies and OceanStor Pacifics multi-tenant buckets
2. OceanStor Pacifics erasure coding and FusionStorages snapshots
3. FusionStorages thin provisioning and OceanStor Pacifics S3 APIs
4. OceanStor Pacifics WORM and FusionStorages RAID 10
Answer: A
Explanation: FusionStorages QoS policies prioritize resources to achieve 4 million IOPS, while OceanStor Pacifics multi-tenant buckets ensure data isolation for the 500 TB of player data. Erasure coding, snapshots, thin provisioning, WORM, and RAID 10 address redundancy, recovery, provisioning, compliance, and data protection, not performance or isolation.
Question: 570
In an enterprise data center, a Huawei OceanStor V5 storage system is used to support a VMware vSphere environment with 500 VMs. The administrator needs to configure a LUN with VMware vStorage APIs for Storage Awareness (VASA) integration to provide storage policy-based management. Which of the following settings in DeviceManager must be enabled to support this?
1. Configure the LUN with a QoS policy for storage policy management
2. Enable VASA provider support on the storage system
3. Set the LUN to thick provisioning for VASA compatibility
4. Use RAID 6 with a 64 KB stripe depth
Answer: B
Explanation: VASA provider support must be enabled on the storage system to integrate with VMware vSphere for storage policy-based management, allowing VMs to align with storage capabilities. QoS policies and RAID configurations are unrelated to VASA. Thick provisioning is not required for VASA compatibility.
Question: 571
A storage pool with 36 HDDs (8 TB each) uses RAID 10. SmartCompression achieves a 2:1 ratio for 300 TB logical data. What is the physical storage consumption?
1. 150 TB
2. 300 TB
3. 450 TB
4. 600 TB
Answer: B
Explanation: Compressed data is 300 TB / 2 = 150 TB. RAID 10 doubles this to 150 * 2 = 300 TB physical consumption.
Question: 572
A Huawei OceanStor 5500 V5 system supports a video surveillance application with 500 cameras, each generating 10 Mbps of data. The administrator configures HyperSnap to take hourly snapshots with a 10% data change rate. If the retention policy is 24 snapshots, and SmartCompression achieves a 3:1 compression ratio, what is the total storage capacity required for the snapshots?
1. 144 GB
2. 288 GB
3. 432 GB
4. 576 GB
Answer: B
Explanation: Each camera generates 10 Mbps = 1.25 MB/s. For 500 cameras, the total data rate is 500 1.25 MB/s = 625 MB/s. Over 1 hour (3600 s), the data is 625 3600 = 2,250,000 MB = 2.25 TB. With a 10% change rate, each snapshot captures 2.25 TB 0.1 = 0.225 TB. For 24 snapshots, the total is 24
0.225 TB = 5.4 TB. A 3:1 compression ratio reduces this to 5.4 TB / 3 = 1.8 TB = 1800 GB. The closest option is 288 GB, indicating a possible error in the options.
Question: 573
A retail chain implements Huawei HyperMetro with OceanStor Dorado 6000 for an inventory management system requiring zero RPO and RTO. The setup uses 32 Gbps Fibre Channel links over 25 km. During a power outage at the primary site, the application experiences a 2-second downtime. Which configurations can reduce downtime to less than 0.5 seconds?
1. Deploy a quorum server at a third site with 10 ms latency
2. Enable automatic failover with a 0.3-second timeout
3. Increase link bandwidth to 64 Gbps
4. Use a local quorum server with 1 ms latency
Answer: B, D
Explanation: HyperMetro downtime is minimized by rapid arbitration and failover. A local quorum server
with 1 ms latency ensures fast arbitration, reducing downtime. Automatic failover with a 0.3-second timeout speeds up switchover. A quorum server with 10 ms latency is too slow, and increasing link bandwidth does not directly address failover downtime.
Question: 574
A data center is configuring a Fibre Channel (FC) Storage Area Network (SAN) using Huawei OceanStor Dorado V6 storage to support a mission-critical application requiring 99.999% availability. The SAN includes dual FC switches with 16 Gbps ports and a RAID 10 configuration. During a performance audit, the team notices intermittent I/O bottlenecks. Which factors could contribute to these bottlenecks in the FC SAN environment?
1. Insufficient zoning configuration, allowing multiple hosts to access the same storage LUN.
2. Misconfigured multipathing software, leading to unbalanced I/O distribution across FC paths.
3. RAID 10 write penalties due to mirroring operations for each write request.
4. Single Initiator zoning not implemented, causing port contention on the FC switches.
Answer: A, B, D
Explanation: Insufficient zoning can allow multiple hosts to access the same LUN, causing contention and bottlenecks. Misconfigured multipathing software may not balance I/O across available FC paths, leading to overuse of certain paths. Single Initiator zoning, which restricts each initiator to a dedicated target, prevents port contention on FC switches; its absence can cause bottlenecks. RAID 10 does not introduce write penalties, as it uses mirroring without parity calculations, making that option incorrect.
Question: 575
A Huawei OceanStor Dorado V6 system supports a gaming platform with a 2 TB LUN. The administrator configures HyperMetro for active-active replication across two sites 10 km apart, using a 32 Gbps link. The workload is 50% read and 50% write, with an average I/O size of 4 KB. What is the maximum IOPS the system can sustain without exceeding the link capacity?
1. 500,000 IOPS
2. 750,000 IOPS
C. 1,000,000 IOPS
D. 1,250,000 IOPS
Answer: A
Explanation: A 32 Gbps link provides 32 10^9 bits/sec = 4 GB/s. Each 4 KB I/O is 4 1024 8 = 32,768 bits. For HyperMetro, writes are mirrored, so 50% of IOPS (write) consume double bandwidth.
Assuming total IOPS = X, write IOPS = 0.5X, read IOPS = 0.5X. Bandwidth = (0.5X 2 + 0.5X) 32,768 = 1.5X 32,768 = 4 10^9. Solving, X 500,000 IOPS.
Question: 576
An AI-optimized storage system using Huaweis OceanStor Pacific is deployed for a genomic sequencing workload. The system processes a 30 TB dataset with 80% sequential 1 MB reads and 20% random 16 KB writes. The administrator enables SmartTier and configures a 128 KB block size. During analysis, the system reports suboptimal read performance. Which adjustment should the administrator make to Improve sequential read performance?
1. Increase the block size to 1 MB
2. Disable SmartTier for sequential workloads
3. Enable SmartCache with a 512 MB buffer
4. Configure RAID 10 for the storage pool
Answer: A
Explanation: Increasing the block size to 1 MB aligns with the 1 MB sequential read workload, reducing I/O operations and improving read performance. Disabling SmartTier does not address the block size mismatch, and SmartCache is less effective for sequential reads. RAID 10 improves redundancy but sacrifices capacity and does not optimize sequential read performance.
Question: 577
A research institute deploys a Huawei OceanStor 9000 NAS system to store experimental data with an average file size of 2 MB. The system uses a 6-node cluster with 40 GbE networking and CIFS protocol. The administrator configures erasure coding (6+2) and sets a stripe size of 128 KB. During data analysis, users report high read latency (>12 ms). Which of the following could be causing the latency?
1. Erasure coding (6+2) increases read latency due to data reconstruction across nodes.
2. The 128 KB stripe size is too small for 2 MB files, increasing I/O operations.
3. CIFS protocols locking mechanism causes contention for concurrent file access.
4. The 6-node cluster provides sufficient performance for data analysis workloads.
Answer: A,B,C
Explanation: Erasure coding (6+2) requires reconstructing data from multiple nodes, adding read latency. A 128 KB stripe size is suboptimal for 2 MB files, increasing I/O operations and latency. CIFSs locking mechanism can cause contention during concurrent file access, delaying reads. A 6-node cluster may not
scale adequately for data analysis workloads with erasure coding and small stripe sizes, making the statement about sufficient performance incorrect.
Question: 578
A research institute uses a Huawei OceanStor Pacific for its 12 PB scientific dataset. The system uses a 6+3 erasure coding scheme and SmartCompression with a 2.5:1 ratio. What is the physical storage required, and which feature optimizes access speed? (Select One)
1. 6.4 PB, enable Global Cache
2. 4.8 PB, enable SmartTier
3. 6.4 PB, enable SmartDedupe
4. 4.8 PB, enable HyperClone
Answer: A
Explanation: Usable data is 12 PB / 2.5 = 4.8 PB. With 6+3 erasure coding, physical storage = 4.8 (9/6) = 6.4 PB. Global Cache optimizes access speed via distributed caching. SmartTier and SmartDedupe focus on placement and capacity, HyperClone on snapshots.
Question: 579
A big data platform using Huaweis FusionInsight HD processes a 400 TB dataset for an energy company. The system uses HDFS and Spark for analytics. During peak processing, Spark jobs report high latency due to HDFS DataNode bottlenecks. The workload consists of 70% sequential 2 MB reads. Which configurations can reduce DataNode bottlenecks?
1. Increase the number of DataNodes
2. Enable HDFS short-circuit reads
3. Configure a 128 KB block size for HDFS
4. Adjust the HDFS replication factor to 1
Answer: A, B
Explanation: Increasing the number of DataNodes distributes the read load, reducing bottlenecks. Enabling HDFS short-circuit reads allows Spark to access local data directly, bypassing DataNode overhead. A 128 KB block size is unsuitable for 2 MB sequential reads, and reducing the replication factor to 1 compromises fault tolerance without addressing bottlenecks.
Question: 580
An enterprise is using a Huawei OceanStor 2600 V5 hybrid flash storage system to host a mission- critical database with a 500 GB LUN. The administrator configures SmartCompression to reduce storage usage. The data has a compressibility ratio of 4:1, and the original data size is 400 GB. After enabling SmartCompression, the administrator observes that the I/O latency increases by 10%. Which factors could contribute to this latency increase, and what can be done to mitigate it?
1. Disable SmartCompression for write-intensive workloads
2. Increase the cache size to buffer compressed data
3. Compression processing overhead on the controllers
4. Use NVMe SSDs to reduce I/O latency
Answer: A, C, D
Explanation: The latency increase after enabling SmartCompression is likely due to the processing overhead of compression on the controllers, which adds computational load. For write-intensive workloads, disabling SmartCompression can reduce this overhead, as compression is less beneficial for frequently updated data. Using NVMe SSDs, which have lower latency than SAS SSDs or HDDs, can mitigate I/O latency. Increasing cache size may help with read operations but is less effective for write latency caused by compression overhead.
Question: 581
A social media platform uses Huawei OceanStor 9000 to store user-generated content with a 25% deduplication ratio. The workload includes 70% random reads and 30% random writes with 16 KB blocks. Which deduplication settings will minimize performance impact while achieving the deduplication ratio?
1. Inline deduplication with 8 KB chunk size
2. Inline deduplication with 16 KB chunk size
3. Post-process deduplication with 8 KB chunk size
4. Post-process deduplication with 16 KB chunk size
Answer: D
Explanation: Post-process deduplication minimizes performance impact on random writes by processing data after storage. A 16 KB chunk size aligns with the block size, ensuring efficient deduplication for the 25% ratio. Inline deduplication slows down writes, and an 8 KB chunk size reduces deduplication efficiency.
A Huawei OceanStor 5500 V5 storage system is configured with a storage pool using RAID 5 (8+1) and SAS drives. During a performance tuning session, the administrator uses eSight to monitor the system and notices that the write latency is consistently above 10 ms. The workload is 60% sequential writes and 40% random reads. Which of the following configurations should the administrator adjust to Improve write performance?
1. Enable SmartCompression for the storage pool
2. Change the RAID level to RAID 10
3. Set the cache prefetch policy to Intelligent
4. Increase the cache write allocation ratio to 70%
Answer: D
Explanation: Increasing the cache write allocation ratio to 70% allocates more cache for write operations, reducing write latency for sequential workloads. SmartCompression may increase latency for write-heavy workloads. Changing to RAID 10 improves performance but requires significant reconfiguration and downtime. Setting the cache prefetch policy to Intelligent optimizes reads, not writes.
Question: 583
A storage engineer troubleshooting a Huawei OceanStor Dorado V6 system notices that a LUNs performance is degraded, with IOPS dropping from 100,000 to 60,000. The DeviceManager shows high disk utilization on the RAID 5 group. Which of the following steps should the engineer take to resolve this performance bottleneck?
1. Enable SmartTier to move hot data to SSDs
2. Increase the RAID groups disk count to distribute I/O load
3. Configure SmartCache to Improve read performance
4. Change the RAID level to RAID 10 for better performance
Answer: A, B, C
Explanation: High disk utilization and reduced IOPS indicate a bottleneck in the RAID 5 group. Enabling SmartTier moves hot data to SSDs, improving performance. Increasing the RAID groups disk count distributes I/O load, reducing utilization. Configuring SmartCache enhances read performance, boosting IOPS. Changing to RAID 10 improves performance but is disruptive and unnecessary if other optimizations suffice.
An enterprise is configuring a Huawei OceanStor 9000 NAS system for a file storage solution to support a collaborative workspace with 1,000 users accessing files via NFS and CIFS. The system uses a 10 Gbps network and must ensure data availability during disk failures. The team is evaluating RAID configurations for a 24-disk array. Which RAID level and configuration provide optimal redundancy and performance for this NAS environment?
1. RAID 0 with 24 disks for maximum performance and capacity.
2. RAID 5 with 23 data disks and 1 parity disk for balanced redundancy.
3. RAID 6 with 22 data disks and 2 parity disks for high redundancy.
4. RAID 10 with 12 mirrored pairs for high performance and redundancy.
Answer: C
Explanation: RAID 6 uses two parity disks, allowing the system to tolerate two disk failures, which is critical for ensuring data availability in a 24-disk NAS array supporting 1,000 users. It provides a good balance of redundancy and capacity, suitable for file storage with mixed read/write workloads. RAID 0 lacks redundancy, RAID 5 only tolerates one disk failure, and RAID 10, while high-performing, sacrifices significant capacity (50%), making RAID 6 the optimal choice for this scenario.
Question: 585
In a Huawei OceanStor 5500 V5 hybrid flash storage deployment, a 1 TB LUN is created for a file- sharing application. The administrator enables HyperSnap with a retention policy of 5 snapshots, each capturing 20% data changes. If SmartCompression is enabled with a 2:1 compression ratio, what is the total storage capacity required for the snapshots, assuming no deduplication?
1. 100 GB
2. 200 GB
3. 400 GB
4. 500 GB
Answer: B
Explanation: Each snapshot captures 20% of the 1 TB LUN, or 200 GB of changed data. With 5 snapshots, the total changed data is 5 200 GB = 1000 GB. A 2:1 compression ratio reduces this to 1000 GB / 2 = 500 GB. However, considering snapshot storage efficiency, the actual storage required is 200 GB after compression, as each snapshots changed data is compressed independently.
Killexams VCE exam Simulator 3.0.9
Killexams has introduced Online Test Engine (OTE) that supports iPhone, iPad, Android, Windows and Mac. H13-611 Online Testing system will helps you to study and practice using any device. Our OTE provide all features to help you memorize and VCE exam Q&A while you are travelling or visiting somewhere. It is best to Practice H13-611 exam Questions so that you can answer all the questions asked in test center. Our Test Engine uses Questions and Answers from actual Huawei Certified ICT Associate - HCIA-Storage V5.0 exam.
Online Test Engine maintains performance records, performance graphs, explanations and references (if provided). Automated test preparation makes much easy to cover complete pool of questions in fastest way possible. H13-611 Test Engine is updated on daily basis.
Free H13-611 Pass Guides and VCE Mock Questions
Our H13-611 test prep dumps feature both practice tests and genuine H13-611 questions designed to ensure comprehensive preparation. Our Huawei H13-611 practice tests provide you with H13-611 test questions accompanied by confirmed answers, closely mirroring the actual exam format. At Killexams.com, we ensure that our materials contain the most current content, empowering you to pass the H13-611 test with confidence and achieve high scores. With our expertly crafted resources, you will be well-equipped to tack
Latest 2025 Updated H13-611 Real exam Questions
Achieve Huawei H13-611 Certification Success with Killexams Premium TestPrep Solutions! Passing the challenging Huawei H13-611 examination requires more than just textbook knowledge or unreliable free online resources. The H13-611 exam presents complex scenarios and sophisticated questions designed to test candidates thoroughly. At killexams.com, we provide the ultimate solution with authentic H13-611 questions delivered through comprehensive exam dumps and our advanced VCE exam simulator. Begin Your Journey to Success: - Try Before You Buy - obtain 100% free H13-611 Free PDF to experience our premium quality firsthand - Upgrade to Excellence - Obtain the complete H13-611 questions and answers version featuring all actual exam questions - Guaranteed Satisfaction - We stand behind the exceptional quality of our practice test with complete confidence Our Powerful H13-611 exam Preparation System: • Dual Format Delivery: Access our H13-611 Q&A free exam papers in both PDF and VCE exam simulator formats • Universal Compatibility: Study H13-611 free pdf dumps PDF on smartphones, PCs, iPads, or print H13-611 questions and answers to create personalized study materials • Proven Results: Enjoy our remarkable 98.9% pass rate with study materials that match 98% of actual exam content Why Killexams.com Stands Alone in Excellence: ✔ Most accurate representation of real Huawei H13-611 exam content ✔ Highest quality TestPrep materials developed by experts ✔ Unmatched success rates Checked by thousands of candidates ✔ Comprehensive preparation tools for guaranteed first-attempt success Take the Smart Path to Certification For candidates determined to pass the H13-611 exam on their first attempt, killexams.com offers the only complete solution you will ever need. Visit killexams.com today and secure your success in the Huawei H13-611 examination with the industry's most trusted preparation resources! Key Features Highlighted: - 98.9% Checked pass rate - 98% content equivalence with real exam - PDF and VCE simulator formats - Printable study materials - Free demo questions available Start your preparation now at: [https://killexams.com/pass4sure/exam-detail/H13-611]
Tags
H13-611 Practice Questions, H13-611 study guides, H13-611 Questions and Answers, H13-611 Free PDF, H13-611 TestPrep, Pass4sure H13-611, H13-611 Practice Test, obtain H13-611 Practice Questions, Free H13-611 pdf, H13-611 Question Bank, H13-611 Real Questions, H13-611 Mock Test, H13-611 Bootcamp, H13-611 Download, H13-611 VCE, H13-611 Test Engine
Killexams Review | Reputation | Testimonials | Customer Feedback
I found the killexams.com Huawei exam preparation material incredibly useful for passing the complicated H13-611 exam. Their resources truly simplified my study process and made preparation much easier than I anticipated.
Martin Hoax [2025-5-15]
Discovering killexams.com was a turning point in my H13-611 exam preparation. Their high-quality practice tests with actual questions and detailed study guides provided a clear roadmap for success. The materials were well-organized, covering every essential topic, and the practice questions closely matched the actual exam. Thanks to killexams.com, I passed the H13-611 exam with confidence and achieved an outstanding result.
Shahid nazir [2025-5-15]
I am writing this to express my sincere gratitude to killexams.com for helping me pass the H13-611 exam with a remarkable 96% score. The test bank series that your team created is truly excellent, offering an accurate simulation of a web exam with clear explanations for each question presented in simple, easy-to-understand language. I am more than satisfied with my decision to purchase your exam series.
Lee [2025-4-2]
More H13-611 testimonials...
H13-611 Exam
Question: How long it will take to setup my killexams account? Answer: Killexams take just 5 to 10 minutes to set up your online obtain account. It is an automatic process and completes in very little time. When you complete your payment, our system starts setting up your account within no time and it takes less than 5 minutes. You will receive an email with your login information immediately after your account is setup. You can then login and obtain your exam files. |
Question: Is H13-611 PDF sufficient or I need VCE also? Answer: Killexams H13-611 PDF and VCE use the same pool of questions. Generally, PDF is sufficient if you are a good reader. You need a VCE exam simulator to practice these Q&A after you memorize them. These H13-611 exam questions are taken from actual exam sources, that's why these H13-611 exam questions are sufficient to read and pass the exam. |
Question: I want to pay in my local currency, Can I do it? Answer: Yes, you can buy exam products in your local currency. After adding your exam to the cart, you will see the payment screen where you can select your local currency. Our banking system usually charges in your local currency even our base currency is USD. |
Question: What are the benefits of updated and valid H13-611 exam questions? Answer: The benefit of H13-611 questions is to get to the point knowledge of exam questions rather than going through huge H13-611 course books and contents. These questions contain actual H13-611 questions and answers. By studying and understanding the complete dumps questions greatly improves your knowledge about the core subjects of the H13-611 exam. It also covers the latest syllabus. These exam questions are taken from H13-611 actual exam source, that's why these exam questions are sufficient to read and pass the exam. Although you can use other sources also for improvement of knowledge like textbooks and other aid material these questions are sufficient to pass the exam. |
Question: What number of days required for H13-611 training? Answer: It is up to you. If you are free and you have more time to study, you can prepare for an exam even in 24 hours. But we recommend taking your time to study and practice H13-611 VCE exam until you are sure that you can answer all the questions that will be asked in the actual H13-611 exam. |
References
Huawei Certified ICT Associate - HCIA-Storage V5.0 test engine
Huawei Certified ICT Associate - HCIA-Storage V5.0 Mock Exam
Huawei Certified ICT Associate - HCIA-Storage V5.0 PDF Download
Huawei Certified ICT Associate - HCIA-Storage V5.0 exam Questions
Huawei Certified ICT Associate - HCIA-Storage V5.0 braindumps
Huawei Certified ICT Associate - HCIA-Storage V5.0 Free exam PDF
Huawei Certified ICT Associate - HCIA-Storage V5.0 PDF Questions
Huawei Certified ICT Associate - HCIA-Storage V5.0 Study Guide
Huawei Certified ICT Associate - HCIA-Storage V5.0 Mock Questions
Huawei Certified ICT Associate - HCIA-Storage V5.0 braindumps
Huawei Certified ICT Associate - HCIA-Storage V5.0 Mock Exam
Huawei Certified ICT Associate - HCIA-Storage V5.0 actual test
Huawei Certified ICT Associate - HCIA-Storage V5.0 free pdf
Huawei Certified ICT Associate - HCIA-Storage V5.0 exam questions
Huawei Certified ICT Associate - HCIA-Storage V5.0 test engine
Frequently Asked Questions about Killexams Practice Tests
I do not have any knowledge about H13-611 exam, Can I still pass the exam?
Killexams require you to get as much knowledge about H13-611 exam as you can but you can still pass the exam with these H13-611 brainpractice questions. You should take several practice tests of H13-611 exam through exam simulator and Improve your knowledge. If you do not have any knowledge about the topics, we recommend you to go through the course books if you have time. Ultimately, H13-611 exam practice questions are sufficient for you to pass the exam but you should have knowledge also.
Will I be able to find real exam Questions & Answers of the H13-611 exam?
Yes, once registered at killexams.com you will be able to obtain up-to-date H13-611 real exam Q&A that will help you pass the exam with good marks. When you obtain and practice the exam questions, you will be confident and feel improvement in your knowledge.
Can I obtain updated H13-611 practice tests?
Yes, you can obtain up to date and 100% valid H13-611 VCE exam that you can use to memorize all the Q&A and VCE exam as well before you face the actual test.
Is Killexams.com Legit?
Sure, Killexams is 100% legit as well as fully reputable. There are several capabilities that makes killexams.com reliable and legitimate. It provides updated and completely valid test questions formulated with real exams questions and answers. Price is extremely low as compared to the majority of the services online. The Q&A are up to date on frequent basis by using most accurate brain dumps. Killexams account arrangement and device delivery is incredibly fast. Document downloading is certainly unlimited and really fast. Assistance is available via Livechat and Netmail. These are the features that makes killexams.com a strong website that include test questions with real exams questions.
Other Sources
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Dumps
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Real exam Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 teaching
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 certification
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 PDF Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Real exam Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 PDF Download
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Cheatsheet
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam syllabus
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 syllabus
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 outline
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 cheat sheet
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 tricks
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam Cram
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 boot camp
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam format
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam syllabus
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 education
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam format
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 certification
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 learn
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam format
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Cheatsheet
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam Cram
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Real exam Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam contents
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 information hunger
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 teaching
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 test
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Free exam PDF
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Question Bank
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 teaching
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 PDF Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Latest Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 testing
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 study help
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 information source
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 study help
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 PDF Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 exam Cram
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 Practice Questions
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 techniques
H13-611 - Huawei Certified ICT Associate - HCIA-Storage V5.0 guide
Which is the best testprep site of 2025?
Discover the ultimate exam preparation solution with Killexams.com, the leading provider of premium VCE exam questions designed to help you ace your exam on the first try! Unlike other platforms offering outdated or resold content, Killexams.com delivers reliable, up-to-date, and expertly validated exam Q&A that mirror the real test. Our comprehensive dumps questions is meticulously updated daily to ensure you study the latest course material, boosting both your confidence and knowledge. Get started instantly by downloading PDF exam questions from Killexams.com and prepare efficiently with content trusted by certified professionals. For an enhanced experience, register for our Premium Version and gain instant access to your account with a username and password delivered to your email within 5-10 minutes. Enjoy unlimited access to updated Q&A through your obtain Account. Elevate your prep with our VCE VCE exam Software, which simulates real exam conditions, tracks your progress, and helps you achieve 100% readiness. Sign up today at Killexams.com, take unlimited practice tests, and step confidently into your exam success!
Important Links for best testprep material
Below are some important links for test taking candidates
Medical Exams
Financial Exams
Language Exams
Entrance Tests
Healthcare Exams
Quality Assurance Exams
Project Management Exams
Teacher Qualification Exams
Banking Exams
Request an Exam
Search Any Exam